WWClient Utility for InTouch® 7.11 and InTouch 8.0 WWClient Utility for InTouch® 7.11 and InTouch 8.0 All Tech Notes and KBCD documents and software are provided 'as is' without warranty of any kind. See the for more information. Topic#: 002022 Created: May 2004 Introduction WWClient is a generic DDE/Suite Link-aware program that can communicate with other DDE/Suite Link applications such as your InTouch application and the Wonderware® I/O Servers. WWClient is useful when you are troubleshooting a Wonderware InTouch application where it will give you easy access to the current value of a particular tagname.

  1. Phil Huber
  2. Wonderware 7.11 Patch
  3. Lake Forest, CA

See for detailed information about how to use WWClient. Installing WWClient For InTouch 8.0 and FactorySuite A² Common Components Due to security concerns, WWClient is not installed when installing the FactorySuite A² Common Components with InTouch 8.0 or later.

Nov 28, 2017 plcforum.uz.ua. International PLC. Can someone share or suggest me where I can download the Patch 6 for InTouch 7.11. Can someone upload wonderware.

To use this version of WWClient, install the wwclient.exe from the zip file to the directory containing the file wwclintf.dll, which is where the FactorySuite A2 Common Components are installed. On a german OS: c: Programme Gemeinsame Dateien ArchestrA On a english OS: C: Program Files Common Files ArchestrA Download WWClient for InTouch 8.0 and FactorySuite A² Common Components. For InTouch 7.11 and FactorySuite® Common Components This version of WWClient should only be used with InTouch 7.11. It should be unnecessary to install WWClient for InTouch 7.11 as it is automatically installed when installing the FactorySuite 2000 Common Components. These Common Components are automatically installed when installing InTouch 7.11 or a version 7.x I/O Server.

To use this version of WWClient install the wwclient.exe from the zip file to the directory containing the file wwclintf.dll, which is where the FactorySuite 2000 Common Components are installed. Download WWClient for InTouch 7.11 and FactorySuite Common Components.

Ujifusa Tech Notes are published occasionally by Wonderware Technical Support. Publisher: Invensys Systems, Inc., 26561 Rancho Parkway South, Lake Forest, CA 92630.

There is also technical information on our software products.

System Requirements The MBSerial 2.0 DAServer supports the following Operating Systems:. Microsoft Windows 2000 Server with Service Pack 4.

Microsoft Windows 2000 Advanced Server with Service Pack 4. Microsoft Windows 2000 Professional with Service Pack 4. Microsoft Windows Server 2003 Standard Edition. Microsoft Windows XP Professional with Service Pack 2. Microsoft Windows XP Embedded with Service Pack 1 Internet Explorer 6.0 is recommended on the computer where the product is installed. Detailed installation instructions are included in the DAServer Installation Guide. It is recommended that you read the DAServer Installation Guide prior to beginning the installation process.

In addition to the procedures described in the DAServer Installation Guide, the following installation requirements and other requirements pertaining to the installation and uninstall orders have to be followed. Local administrator privileges are required to install a DAServer. If there are prior versions of DAServers installed on the computer, MBSerial DAServer is able to detect them and performs an upgrade on this product. That is, MBSerial DAServer 2.0 will allow customers to upgrade from previous versions of other DAServers without an uninstall of those DAServers.

In addition, components, which are common to all DAServers on the system, such as the DASEngine and DAServer Manager, will also be upgraded. During installation, the UI states that the feature will be installed on the local disk drive.

This is not forced, and you can install on a network drive. However, installing on a network drive is not a valid configuration option. Local installation is a requirement. Installation Order Requirements The installation for the DAServers and other Wonderware FactorySuite™ products on the same computer must follow the order as outlined. A DAServer must always be installed last. (If required) - InTouch™ 7.11 followed by application of the latest available InTouch patch. (If required) - Legacy I/O Servers™.

7.11

DAServer(s) This installation order will ensure that any differences, which may exist in the common components included with individual product releases, will install and run without version conflicts. In case of any future patch on the installed Wonderware FactorySuite products, follow the particular installation instructions from the patch. Uninstall Order Requirements After installing a DAServer on a computer with other Wonderware FactorySuite products, the following applies:. If any Wonderware FactorySuite product is uninstalled from the computer, all other Wonderware FactorySuite products must be uninstalled and reinstalled. Note: ArchestrA™ products, such as InTouch™ 8.0 or greater, do not require any installation/uninstall order with the DAServers. Wonderware DAServer Compatibility with Other FactorySuite Products on the Same Computer At the time of this release, InTouch, Version 7.11 with Patch 05a or greater, and Wonderware FactorySuite 2000 I/O Servers, previously released with support for Windows 2000 or greater, are the supported Wonderware product combinations on the same computer with the DAServers. Please check the FactorySuite Product version-compatibility matrix at to determine if the product-version combination associated with this install is supported.

Non-Wonderware Product Issues L00021068: Although Wonderware DAServers can communicate with multiple client protocols at the same time, you should be aware of the advantages and disadvantages of the technologies used for any particular protocol. For example, the OPC Data Access protocol is based on Microsoft COM/DCOM technology. The DCOM technology has an inherent pinging mechanism that requires six (6) minutes before a DCOM connection is declared as timed-out. As a result, there may be a chance that when the DAServer is connected remotely with an OPC client and the network is interrupted, a delay of six (6) minutes may be experienced in the OPC client program before declaring the connection to the DAServer a failure. Please note that this is expected; the DAServer remains active and continues to provide data connectivity to other clients that have good network connections. More information on the DCOM pinging mechanism can be found in Sections 2.5 and 2.5.1 of the specifications Distributed Component Object Model Protocol.

DCOM/1.0 from Microsoft. Installation Long Computer Name: The computer name used by NetBIOS is limited in length to MAXCOMPUTERNAMELENGTH (for instance, the limitation is 16 characters for Windows NT 4.0). That is why, when installing a DAServer on a computer with a long name (that is, 'MyVeryLongComputerName'), you may have issues accessing the DAServer diagnostics.

WWLogger: After installing this DAServer, the pre-existing WWLogger™ output will be redirected to the new Log Viewer. First Activation: When installed on a Windows 2000 operating system, the first time the DAServer is activated, a 'server busy' message may appear. Subsequent activation of the DAServer will not produce this message.

Uninstall L00005951: Uninstalling an activated DAServer does not give any warning message, and the active connection with the client would be lost. L00009971: Canceling an uninstallation process may cause the DAServer to be set to 'Not a Service' mode if two DAServers are present on the same node. Configuration The ModbusSerial DAServer can be configured to connect a large network of Modbus PLCs across different serial ports. System resources such as CPU cycles, physical memory, and system threads are consumed with each PLC that is configured into the DAServer. You must specify appropriate device group update-interval and reply-timeout values for the number of PLCs and the baud rate of PLC being connected to the serial port(s).

Patch

Configuring a high number of PLCs to a serial port can potentially reduce the performance of this DAServer. The DAServer Manager CPU Utilization: The DAServer performance may be impaired if the CPU utilization reaches and remains at 100%; the DAServer may then become user-unresponsive. Keyboard Navigation: If using only the keyboard for navigation after starting the DAServer Manager, you will not be able to get to the dialog boxes and other boxes on the configuration view. Also, once in the dialog boxes, using the mouse, you can only move in the downward direction using the TAB key. Pressing the SHIFT+TAB keys to go back does not work. Keyboard interfaces on all faceplates may not work in accordance with Microsoft conventions. Using the mouse to navigate in the DAServer Manager is recommended.

Phil Huber

Hot Configuration: Modifying the Default Update Interval, while the DAServer is communicating with a PLC, will not take effect until the current update interval has completed. Watchdog Item: The historically reserved item 'Watchdog' can be added, but will log the following two messages:. Unable to add item '.Watchdog' with access path 'xyz'. ProtCreatePoint::AddItems method failed (hr=0x1) for item name='watchdog' These messages are spurious, as the item itself will work. Device Groups: Attempting to rename a Device Group with the same name but different case (upper or lower) will fail. Device Groups are case insensitive and, therefore, treat upper and lower cases of a character as the same character. L00003667: System items do not show in the DAServer Manager Diagnostics, unless subscribed to by a client.

L00004239: The DAServer Manager does not automatically refresh when the DAServer on a remote node is uninstalled or has gone off-line/online. DAServer-Generic L00010798: The Warning message in Log Viewer to indicate clamping of values because of a type conversion is sometimes incorrect. The text for '.from x to y failed.' Very often has illegible characters for 'x.' L00012809: The $SYS$WriteComplete system tag does not display the correct value following an InTouch reinitialize I/O during a recipe download.

L00020512: Transaction status (completed/error) was not passed to the OPC Plug-in during a node tear-down and rebuilt, resulting in the OPC Plug-in timing out 10 minutes later. After the node was rebuilt, a Read transaction was completed successfully with 0 (zero) items according to the server diagnostics. However, the OPC client did not get any acknowledgement until 10 minutes later when the OPC Plug-in timed out. MBSerial-DAServer-Specific If you generated a configuration from the previous version of MBSerial DAServer, upon upgrading to Version 2.0, please confirm the setting for 'Swap 16-bit registers (Longs)' and 'Swap 16-bit registers (Reals).' The 'Swap 16-bit registers (Longs)' was labeled as 'Use Concept data structures (Longs)' in Version 1.0. The 'Swap 16-bit registers (Reals)' was labeled as 'Use Concept data structures (Reals)' in Version 1.0. 'If the 'Swap 16-bit registers (Longs) and/or 'Swap 16-bit registers (Reals)' check box is/are checked, MBSerial DAServer Version 2.0 will return the data exactly to what is shown in the Schneider’s Concept programming software. If the 'Swap 16-bit registers (Longs)' and 'Swap 16-bit registers (Reals)' check box is unchecked, MBSerial DAServer will return the data with the register values reversed.

The Wonderware ModbusSerial DAServer is a Microsoft ® Windows ® application program that acts as a communications protocol server. It allows other Windows application programs access to data in the Schneider’s Modicon-family of controllers (also referred to as devices), including the TSX Quantum, TSX Momentum, and the Modicon Micro, that are connected to the DAServer through either the computers’ serial ports, data modem, or radio modem, using the Modbus protocol.

The ModbusSerial DAServer also supports other Generic 4-digit, 5-digit, and 6-digit Modbus controllers supporting the Modbus protocol, provided the messaging used by these controllers conforms to the specifications described in the MODBUS Application Protocol Specification V1.1a dated June 4, 2004. While the DAServer is primarily intended for use with Wonderware InTouch ® (Version 7.11 Patch 02 and later), it may be used by any Microsoft Windows program capable of acting as a DDE, SuiteLink™, or OPC DA client that can also coexist with FactorySuite™ 2000 and greater.

The MBSerial DAServer documentation set includes the following guides: 1. DAServer Installation Guide.

This online Help provides information on installing the DAServer, including options for installing all components of the system or just individual ones. These include the DAServer Manager (including configuration components of the DAServer), the DAServer (including OPC protocol capabilities), and the DDE/SuiteLink Plug-In (for communicating with the legacy Wonderware products). This Help file can be accessed from CD-DASMBSerial as Install-MBSerial.chm. Change Network Account Online Help. This Help documentation describes the tool you can use to manage credentials for node-to-node communications between ArchestrA™ components. This documentation can be accessed from the application's Help. Protocol s Guide.

This guide, provided in PDF format, provides background information on the main protocols used between components of the Wonderware products. A protocol is the set of rules and standards for enabling computers to connect and exchange data over the network.

This guide also includes information on setting up and using some of these protocols. The Protocols Guide is available in the CD-ROM directory UserDocs English. ModbusSerial DAServer User's Guide. This guide describes the user interface and functions of the Wonderware MBSerial DAServer. DAServer Manager User's Guide. This documentation describes the runtime Configuration, Diagnostics, and Activation/Deactivation aspects of a Data Access Server (DAServer). These aspects of any DAServer are maintained through the generic component called the DAServer Manager.

License Utility Guide. This guide describes the FactorySuite 2000 (Version 7.1) licensing strategy and explains how to use the License Utility to install license files and browse valid license files on the network. LogFlag Editor User's Guide. This documentation describes the user interface and functions of the LogFlag Editor utility. This utility can be opened only from the Log Viewer, a part of the System Management Console suite of utilities. Log Viewer User's Guide.

Wonderware 7.11 Patch

This guide provides information about the Logger™ and the Log Viewer snap-in to the System Management Console. Documents numbers 3 through 8 are provided in the PDF form and can be printed; they are available in the CD-ROM directory UserDocs English.

Also, information included in these guides is provided in online Help, which can be accessed from the MBSerial DAServer's Help. Viewing PDF Documentation The documentation describing how to use this product is included on the CD in PDF format. Viewing these guides requires the installation of the Adobe's Acrobat Reader.

• You can only upload videos smaller than 600MB. Paint tool sai pencil brushes. • You can only upload photos smaller than 5 MB.

Lake Forest, CA

This utility is not included on this CD, but it can be downloaded for free from the Adobe Web site at the following Web address: After downloading the file from Adobe, you must run the executable to install it on your computer. Follow the typical installation routine. After installation, you can either open the Acrobat Reader and select a user's guide from the File menu, or double-click a user's guide on the CD in Windows Explorer. © 2005 Invensys Systems, Inc. All Rights Reserved.